Skip to content
Home > Products > Strobe Lights
Sort By:
Page of 1
BRK RM4 Relay Module - Activates Auxuliary Warning Devices - For Use with BRK and First Alert Smoke Alarms BRK Relay Module - Activates Auxuliary Warning Devices - For Use with BRK and First Alert Smoke Alarms

The RM4 is designed to activate an auxiliary device when an alarm is initiated. The RM4 Relay is intended for use with BRK and First Alert Smoke, Heat and Carbon Monoxide Alarms. The relay contacts will activate whenever any interconnected alarm sounds. The relay contacts will automatically deactivate a few seconds after the alarm stops sounding. The RM4 may be wired next to an AC alarm or from a remote location. This relay must be installed in a junction box.

Interconnects smoke alarms, carbon monoxide alarms and heat alarms with:
Lights,Bells,Door Closers,Sirens,Exit Signals,Escape Lights,Exhaust Fans,Other Auxiliary Devices

Our Price: $15.95 Free 2-3 Day Shipping-ALL ORDERS SHIP IN 24HRS
BRK First Alert SL177 Hardwired Hearing Impaired Strobe Light BRK First Alert SL177 Hardwired Hearing Impaired Strobe Light

NOT A SMOKE DETECTOR, ONLY STROBE
The BRK SL177 is a hardwired addition to your smoke / Carbon Monoxide detection system. Usually used in institutional applications, the dual mode strobe light provides a visual representation of the alarm sound for the hearing impaired. This ADA compliant model is a great way to make sure you are ADA compliant while ensuring the safety of others. In addition to providing a bring strobing flash, the BRK SL177 will flash in patterns based on the alarm to better prepare thehearing imparied. The SL177 meets UL 1971 standard by flashing at an average rate of 60 times per minute.
The BRK SL177 oprates on 120V standard line voltage and features a green indicator LED to identify if the unit is receiving power. This unit can be interconnected with up to 18 devices including Smoke Alarms, Carbon Monoxide Detectors, Bells, Sirens, Repeaters, etc. The BRK SL177 will activate once an interconnected alarm is triggered.

SPECS
Model # SL177
Warranty 10 Years
Weight 9.9 oz
Dimension 5.6" dia x 3.3"H
Operating Voltage 120V AC 60Hz
Operating Current .05 amps (standby/alarm)
Temperature Range 40°F (4°C) to 100°F (38°C)
Humidity Range 10% to 90% relative humidity (RH)
Test/Silence To test this strobe light you must activate the test button of each inter-connected, smoke, CO or heat alarm.
Interconnections Up to 18 units of First Alert or BRK Smoke, CO and Heat Alarms. Maximum of 12 smoke alarms. See user's manual for details.
Indicator Lights/Sounds
AC Power: Constant Green LED
Listing Listed to UL1971 Standard

Our Price: $54.95 Free 2-3 Day Shipping-ALL ORDERS SHIP IN 24HRS
BRK First Alert 7010BSL Hardwired Photoelectric Smoke Detector with Battery Backup & Strobe

The First Alert BRK Model Number 7010BSL is a hardwired photoelectric smoke alarm with integrated 177 candela strobe light. The First Alert 7010BSL not only has the ADA approved strobe light but the best smoke detection you can get, Photoelectric. The 7010BSL also has smart strobe technology which will pulse in different rates to tell you if you have smoke or carbon monoxide. YOU MUST HAVE A CO DETECTOR within your system and interconnected to this unit for that to work. If you are deaf or simply have some hearing loss the 7010BSL is your best option to protect your home. The First Alert 7010BSL is specifically designed for residential and institutional applications including sleeping rooms of hospitals, hotels, motels, dormitories and other multifamily dwellings as defined in standard NFPA 101. Model 7010BSL complies with UL217, UL1971, CSFM, NFPA 72, HUD, FHA and other agencies that model their codes after the above agencies. They meet building codes where AC with battery backup, silence, photoelectric smoke alarms are required. The alarms are interconnectable with up to 18 devices, of which 12 can be smoke alarms. One device includes both a strobe light and photoelectric smoke alarm and only requires one electrical box. Saves installation time.

SPECS:
Model # 7010BSL
177 CANDELA XENON STROBE. Powerful 177 candela xenon strobe light provides effective visual warning to hearing impaired residents.
1 Hz FLASH RATE. 60 fl ashes per minute rate meets ADA, ANSI 117.1
NFPA 72 and UL1971 requirements for visual signal devices.
OPTIPATH 360 TECHNOLOGY. Provides 360 degrees of direct access to the smoke sensing chamber.
BATTERY BACKUP.Two AAA batteries provide backup for the smoke alarm during power outages. (Note: will not power the strobe light).
Weight 10.9 oz
Dimension 5.1" dia x 4.0"H
Operating Voltage 120V AC 60Hz w/ two AAA battery backup for smoke alarm (Note: will not power the strobe light).
Voltage Range: 108V AC to 132V AC Operating Current 0.05/0.60 amps (standby/alarm)
Temperature Range 40°F (4°C) to 100°F (38°C)
Humidity Range 10% to 90% relative humidity (RH)
Audio Alarm 85dB at 10 feet
Test/Silence Electronically simulates smoke condition, causing the unit to alarm
Press and hold test/silence button Alarm Reset Automatic when smoke clears
Interconnections Up to 18 units of First Alert or BRK Smoke, CO and Heat Alarms.
Maximum of 12 smoke alarms. See user's manual for details.
Smoke Sensor Photoelectric
Strobe Light 177 candela Xenon strobe Flash Rate: 1 Hz. Smoke Alarm: Constant approx. 1 fl ash per second CO Alarm: Intermittent approx. 1 flash per second for four flashes, then 5 seconds off. Pattern is repeated.
Indicator Lights/Sounds AC Power: Constant Green LED DC Power: Intermittent Red LED Local Alarm: Red LED flashes rapidly Remote Alarm: Red LED out.
Listing Listed to UL217 & UL1971 Standards

Our Price: $79.95 Free 2-3 Day Shipping-ALL ORDERS SHIP IN 24HRS***BACKORDERED UNTIL 10/27/17***